| Bio-pharmaceutical quality stainless steel water purification
sanitary fittings, valves and tubing for drinking water, bottled water,
wells, beverages, pharmaceutical fluids, fermentation, distillation.

Drinking Water Silver Ionization chamber, 2 inches ID.
Contains single solid 99% pure silver anode electrode, length 6 inches.
Recommended ionizer is our CS-2000 high
frequency 2 ampere model at
http://www.biophysica.com/ionizer.htm Silver has
scientifically documented safe antimicrobial residual potency.
Look at
http://www.biophysica.com/silver.htm and at
http://www.biophysica.com/colloidal_scientific_references.html
Our constant current high frequency generators produce
nanocrystalline and atomic elemental particles of silver charged with a
high Zeta Potential. These are not ions, which can cause Argyria.
Nanoparticles are catalysts and are not affected by the hydrochloric
acid of the stomach do not enter into the biochemical metabolism of the
body and are excreted unchanged through the kidney. |
| Components are designed and manufactured in
compliance with ASME BPE specifications for the biotechnology and
pharmaceutical processing industries. The stainless steel chamber is
designed for any liquid flow process or high purity utility application
where cleanability, sterility, dimensional integrity, and materials of
construction are critical. Series 25 fittings are designed and
manufactured according to strict tolerances for ovality, end face
squareness, wall thickness, and material chemistry. Series 25 products
are also compatible with clean-in-place (CIP) and steam-in-place (SIP)
processes. CHAMBER: Ionization Tee chamber 2
inches ID is available in three standard surface finish configurations:
-1MP Option: Internal surface mechanically polished per ASME BPE SFF1
standard (20 Ra maximum)
Outer surface is mechanically polished to a 32 Ra finish with welds
ground flush and polished
-5 Option: Internal surface mechanically polished and electropolished
per ASME BPE SFF5 standard (20 Ra maximum)
Outer surface in as-welded condition, with a light scotch-brite
buff applied to the mill finish
-5MP Option: Internal surface mechanically polished and electropolished
per ASME BPE SFF5 standard (20 Ra maximum)
Outer surface is mechanically polished to a 32 Ra finish with
welds ground flush and polished
CLAMP : Clamp is made of
304L stainless steel in 2-piece, 3-piece, and high pressure bolt styles.
They are designed to facilitate fast system assembly and disconnect
quickly for easy access to the process system, yet are secure and
fissure free.
END-CAP: HPS
Series 25 encaps are available in two standard surface finish
configurations:
-1MP Option ID mechanically polished per ASME BPE SFF1 standard (20 Ra
maximum)
OD is mechanically polished to a 32 Ra finish with welds ground flush
and polished
-5MP Option ID mechanically polished and electropolished per ASME BPE
SFF5 standard (20 Ra maximum)
OD is mechanically polished to a 32 Ra finish with welds ground flush
and polished
GASKET:
Biophysica offers a variety of gaskets to promote easy system
installation in the most demanding customer applications. Gaskets are
available standard or flanged. Standard is lower cost. Flanged has a
better fit and positioning. The compounds offered include Viton,
TeflonŽ, peroxide cured and platinum-cured Silicone, Buna-N and EPDM,
with a high chemical and sanitary purity. Certifications of Compliance
for elastomer gaskets are available on request
|
Property: |
Buna-N |
TeflonŽ |
Silicone |
VitonŽ |
EPDM |
|
Temperature Range: |
-40° to 225° F |
-110° to 450° F |
-80° to 450° F* |
-20° to 400° F |
-55° to 275° F |
| Acid Resistance |
Good |
Excellent |
Good |
Good |
Good-Excellent |
| Petroleum Oil |
Excellent |
Excellent |
Good |
Excellent |
Poor |
| Vegetable Oil |
Good |
Excellent |
Good |
Excellent |
Good |
| Abrasion Resistance |
Good |
Excellent |
Good-Excellent |
Good |
Good-Excellent |
| Tensile Strength |
Fair-Good |
Excellent |
Good |
Good-Excellent |
Good-Excellent |
| Tear Resistance |
Good |
Excellent |
Excellent |
Fair |
Good |
| Steam Resistance |
Good |
Excellent |
Good |
Good |
Good |
| Flame Resistance |
Poor |
Excellent |
Poor |
Good |
Poor |
| Electrical
Properties |
Poor |
Excellent |
Excellent |
Good |
Excellent |
| Ozone Resistance |
Fair |
Excellent |
Excellent |
Excellent |
Excellent |
| Weather Resistance |
Good |
Excellent |
Excellent |
Good |
Excellent |
| Certification |
3A 18-03
FDA 21 CFR 177.2600 |
3A 20-19
FDA 21 CFR 177.1550 |
USP Class VI,
Section 88
3A 18-03
FDA 21 CFR 177.2600 |
3A 18-03
FDA 21 CFR 177.2600 |
3A 18-03
FDA 21
CFR 177.2600 |
| Notes |
Not recommended
for use with Oxonia |
Clamp pressure
ratings do not apply to Teflon gaskets |
* Peroxide cured
silicone is good to 450° F. Platinum cured silicone is not
recommended over 200°F. |
FERRULES: This is a piece of stainless steel
tubing 2.25 inches in length with a flange for attachment to other pipes
using a clamp.
Silver ionization
has not yet been approved for sale in Canada. |